BacT/ALERT® 3D: Healthcare

Optimizing Collection to Care

The BacT/ALERT® 3D instrument is a state-of-the-art, automated microbial detection system. The BacT/ALERT® system offers advantages in every dimension of microbial detection testing.

From its space-saving modular design to its easy touch-screen operation and flexible data management options, every size laboratory can perform microbial detection with the BacT/ALERT® 3D.

USES

BacT/ALERT® 3D is used for sepsis risk stratification and monitoring for the presence or absence of microorganisms in:

  • Blood
  • Sterile body fluids
  • Mycobacteria

FEATURES AND BENEFITS

Because it's so easy to use, BacT/ALERT® 3D saves time, facilitates cross-training and helps prevent errors. This system offers immediate bottle recognition, putting you in control of bottle loading and unloading and virtually eliminating bottle handling errors during microbial detection testing. The system's automatic, built-in quality control, along with a low false positive rate and a rapid response time of this system, means you do more in less time with greater accuracy.

The latest generation of BacT/ALERT® Culture Media brings the most advanced, innovative microbial growth and detection technology to your laboratory. BacT/ALERT® media provide unsurpassed performance, in the detection of a wide variety of microorganisms including bacteria, fungi, and yeasts.

With flexible data management options of an automated microbial detection system, and available with many different system options, BacT/ALERT® 3D allows you to choose the best configuration for your laboratory.

Plastic Bottles Mean Safety
Safety is an important consideration for any microbial testing. bioMérieux is committed to providing the safest products possible to the microbiology laboratory. BacT/ALERT® bottles are made of unbreakable plastic to protect them from breakage. They are also lightweight to reduce the cost of disposal and shipping.

Click here to learn more about BacT/ALERT® collection bottles

Click here to learn more about WorkSafe Blood Culture Collection Kits

BACT/ALERT® 3D: HEALTHCARE FEATURES & SPECS

Results are the most important aspect of any microbial detection system. Built on bioMérieux's patented colorimetric technology, the BacT/ALERT® 3D demonstrates unsurpassed recovery of a wide range of organisms.

BacT/ALERT® 3D System Options
We've designed a microbial detection system to meet your individual needs. The modular design of the BacT/ALERT® 3D enables the most flexible, ergonomic configuration to meet space limitations. The control module manages all bottle inventory and data, while the incubator module performs the testing.

BacT/ALERT® 3D Combination Module – The BacT/ALERT® 3D Combination Module is an integrated system that uses only 20 inches of bench space. Now, even the smallest laboratories can get the highest-quality microbiology test results on-site.

BacT/ALERT® 3D 60 – The BacT/ALERT® 3D 60 is the latest addition to the BacT/ALERT® 3D product range. Our space-saving design has been optimized still further. Combined with all the advantages of the larger volume modules, the BacT/ALERT® 3D 60 ensures all laboratories can benefit from this technology. BacT/ALERT® 3D 60 easily handles an annual workload of up to 3,600 blood/body fluid culture bottles, or up to 500 mycobacteria tests.

Downloads:

BACT/ALERT® 3D: HEALTHCARE USES

For Clinical Laboratory:

  • Microbial detection
  • Sepsis and quality control testing
  • Monitoring for the presence or absence of microorganisms
  • Data management/integration
  • Instrumentation interfacing

For Clinicians and Administrators:

  • Workload efficiency
  • OSHA guidelines
  • Patient/employee safety
  • Data management/integration
  • Cost savings

BACT/ALERT® 3D: HEALTHCARE CULTURE MEDIA

BacT/ALERT® Culture Media brings an advanced automated microbial growth and detection technology to your laboratory. BacT/ALERT® media provide unsurpassed performance, workflow efficiencies and safety. bioMérieux is the only manufacturer to offer blood culture media in plastic bottles.

BacT/ALERT® Healthcare Culture Media Selection Guide

Bottle Type

Catalog No.

Media Formulation

Specimen Type

Specimen Volume

BacT/ALERT® SA Standard Aerobic

259789

40 mL supplemented tryptic soy broth (TSB)

Blood or normally sterile body fluid (SBF)

Up to 10 mL

BacT/ALERT® SN Standard Anaerobic

259790

40 mL TSB

Blood or SBF

Up to 10 mL

BacT/ALERT FA FAN® Aerobic

259791

30 mL peptone-enriched TSB, supplemented with BHI solids and activated charcoal

 

Blood or SBF

Up to 10 mL

 

BacT/ALERT® FN FAN Anaerobic

259793

40 mL peptone-enriched TSB, supplemented with BHI solids and activated charcoal

Blood or SBF

Up to 10 mL

 

BacT/ALERT® PF Pediatric FAN

259794

20 mL peptone-enriched TSB, supplemented with BHI solids and activated charcoal

Blood

Up to 4 mL

BacT/ALERT® MP Mycobacteria Process

259797

10 mL supplemented Middlebrook 7H9 broth. Use with 259760.

Processed specimen or SBF other than blood

 

0.5 mL

 

MB/BacT® Mycobacteria Antibiotic Supplement Kit

259760

MB/BacT® Reconstitution Fluid: oleic acid, glycerol, bovine serum albumin, and amaranth in water. MB/BacT® Antibiotic Supplement Lyophilized supplement with: amphotericin B, azlocillin, nalidixic acid, polymyxin B, trimethoprim, and vancomycin.

Add 0.5 mL to each BacT/ALERT® MP bottle

 

N/A

BacT/ALERT® MB Mycobacteria Blood

251011

29 mL supplemented Middlebrook 7H9 broth with glycerol and SPS. Use with 259877.

Whole blood

3–5 mL

 

MB/BacT® Enrichment Fluid

259877

Bovine serum albumin, sodium chloride, oleic acid, and saponin in water

Add 1.0 mL to each BacT/ALERT® MB bottle

N/A

 

BACT/ALERT® 3D: HEALTHCARE SOFTWARE

OBSERVA®:

OBSERVA data management software efficiently consolidates data and results as part of bioMérieux’s integrated solution for patient care. A single workstation manages patient data integration from both the BacT/ALERT® 3D and VITEK® 2. OBSERVA helps meet all your reporting needs and helps maintain the priorities of quality of care and cost control. Click here to view a demo of OBSERVA.

BacT/ALERT® 3D Signature:

The BacT/ALERT® 3D Signature is a powerful microbiology workstation with comprehensive capabilities. It is ideal for higher-volume laboratories, university settings, or where expanded flexibility in operating routines, reporting and data management are needed.

BacT/ALERT® 3D Select:

The ideal choice for routine microbial testing in areas where expanded data management or laboratory information system (LIS) connectivity is not needed.

BacT/ALERT® 3D SelectLink:

The perfect option for routine microbial testing where exchange of basic data and results with the LIS is a necessity.

BACT/ALERT® 3D: HEALTHCARE PUBLICATIONS

Standard Media Recovery:

Mirret S, Reller LB, Petti CA, Woods CW, Vazirani B, Sivadas R, and Weinstein MP. Controlled Clinical Comparison of BacT/ALERT® Standard Aerobic Medium with BACTEC Standard Aerobic Medium for Culturing Blood. J. Clin Microbiol. 2003; 41(6):2391-2394.

Bernard D, Verschraegen G, Claeys G, Lauwers S, Rosseel P. Bilophila wadsworthia bacteremia in a patient with gangrenous appendicitis. Clin Infect Dis. June 1994;18:1023-1024.

Standard vs. FAN® Media:

Weinstein MP, Mirrett S, Reimer LG, Wilson ML, Smith-Elekes S, Chuard CR, Joho KL, Reller LB. Controlled evaluation of BacT/ALERT® standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia. J Clin Microbiol. 1995;33(4):978-981.

Wilson ML, Weinstein MP, Mirrett S, Reimer LG, Feldman RJ, Chuard CR, Reller LB. Controlled evaluation of BacT/ALERT® standard anaerobic and FAN anaerobic blood culture bottles for the detection of bacteremia and fungemia. J Clin Microbiol. 1995;33(9):2265-2270.

McDonald LC, Fune J, Gaido LB, Weinstein MP, Reimer LG, Flynn TM, Wilson ML, Mirrett S, Reller LB. Clinical importance of increased sensitivity of BacT/ALERT® FAN aerobic and anaerobic blood culture bottles. J Clin Microbiol. 1996;34(9):2180-2184.

Mirrett S, Everts RJ, Reller LB. Controlled Comparison of Original Vented Aerobic FAN Medium with New Nonvented BacT/ALERT® FA Medium for Culturing Blood. J Clin Microbiol. 2001;39(6):2098-2101.

Mirrett S, Petti CA, Woods CW, Magadia R, Weinstein MP, Reller LB. Controlled Clinical Comparison of the BacT/ALERT® FN and the Standard Anaerobic SN Blood Culture Medium. J Clin Microbiol. 2004;42(10):4581-4585.

FAN® vs. BACTEC® Plus:

Ziegler R, Johnscher I, Martus P, Lenhardt D, Just HM. Controlled clinical laboratory comparison of two supplemented aerobic and anaerobic media in automated blood culture systems to detect bloodstream infections. J Clin Microbiol. 1998; 36(3):657-661.

Pohlman JK, Kirkley BA, Easley KA, Basille BA, Washington JA. Controlled clinical evaluation of BACTEC Plus Aerobic/F and BacT/ALERT® aerobic FAN bottles for detection of bloodstream infections. J Clin Microbiol. 1995;33(11):2856-2858.

Jorgensen JH, Mirrett S, McDonald LC, Murray PR, Weinstein MP, Fune J, Trippy CW, Masterson M, Reller LB. Controlled clinical laboratory comparison of BACTEC Plus Aerobic/F Resin medium with BacT/ALERT® Aerobic FAN medium for detection of bacteremia and fungemia. J Clin Microbiol. 1997;35(1):53-58.

Body Fluids:

Bourbeau P, Riley J, Heiter BJ, Master R, Young C, Pierson C. Use of the BacT/ALERT® blood culture system for culture of sterile body fluids other than blood. J Clin Microbiol. 1998;36(11):3273-3277.

Alfa MJ, Degagne P, Olson N, Harding KM. Improved detection of bacterial growth in continuous ambulatory peritoneal dialysis effluent by use of BacT/ALERT® FAN bottles. J Clin Microbiol. 1997;35(4):862-866.

Glass vs. Plastic Bottles:

Snyder JW, Munier GK, Bostic GD, Bozigar PS, Hanna R. Evaluation of a Plastic Nonvented Aerobic Blood Culture bottle for Use with the BacT/ALERT® Microbial Detection System. J Clin Microbiol 2002; 40(12): 4757-4759.

Petti, CA, Mirrett S, Woods CW, and Reller LB. Controlled Clinical Comparison of Plastic versus Glass Bottles of BacT/ALERT® PF Medium for Culturing Blood from Children. J Clin Microbiol 2005; 43(1): 445–447

Petti CA, Mirrett S, Woods CW, Reller LB, Controlled clinical comparison of plastic and glass bottles of BacT/ALERT® FA medium for culturing organisms from blood of adult patients. J Clin Microbiol 2005; 43(4), 1960-1962

Pediatric:

Alpern E, Alessandrini E, Bell L, Shaw K, McGowan L. Occult bacteremia from a pediatric emergency department: current prevalence, time to detection, and outcome. Pediatrics. 2000;106(3):505-511.

McGowan K, Foster J, Coffin S. Outpatient pediatric blood cultures: time to positivity. Pediatrics. 2000;106(2):251-255.

Krishner KK, Gibb P, CorbettS, and Church DEIDRE. Comparison of the BacT/Alert® PF Pediatric FAN Blood Culture Bottle with the Standard Pediatric Blood Culture Bottle, the Pedi-BacT J Clin Microbiol. 2001;39(8): 2880-2883.

BacT/ALERT® vs. ESP®:

Welby-Sellenriek PL, Keller DS, Ferrett RJ, Storch GA. Comparison of the BacT/ALERT® FAN aerobic and the Difco ESP 80A aerobic bottles for pediatric blood cultures. J Clin Microbiol. 1997;35(5):1166-1171.

Doern G, Barton A, Rao S. Controlled comparative evaluation of BacT/ALERT® FAN and ESP 80A aerobic media as means for detecting bacteremia and fungemia. J Clin Microbiol. 1998; 35(9):2686-2689.

Mycobacteria, Yeast and Fungi:

Alcaide F, Benitez MA, Escriba JM, Martin R. Evaluation of the BACTEC MGIT™ 960 and the MB/BacT systems for recovery of mycobacteria from clinical specimens and for species identification by DNA AccuProbe. J Clin Microbiol. 2000;38(1):398-401.

Crump J, Tanner DC, Mirrett S, McKnight CM, Reller LB, Controlled Comparison of BACTEC 13A, Myco/F Lytic, BacT/ALERT® MB and Isolator 10 Systems for Detection of Mycobacteremia. J Clin Microbiol 2003;41(5):1987-1990.

McDonald, L., Weinstein, M., Fune, J., Mirrett, S., Reimer, L., Reller, B., Controlled Comparison of BacT/ALERT® FAN Aerobic Medium and Bactec Fungal Blood Culture Medium for Detection of Fungemia, J Clin Microbiol 2001:39(2): 622–624.

Other:

Paul P. Bourbeau and Janice K. Pohlman, Three Days of Incubation May Be Sufficient for Routine Blood Cultures with BacT/Alert® FAN Blood Culture Bottles. J Clin Microbiol. 2001;39(6):2079-2082.

Seegmuller I, Eschenbach U, Kamereck K. Sensitivity of the BacT/ALERT® FA medium for detection of Pseudomonas aeruginosa in pre-incubated blood cultures and its temperature dependence. J Med Microbiol, (2004); 53. 869-874.

Pioneering diagnostics