The MDA II is a fully automated analyzer for clotting, chromogenic
assays and immunoassays. This is the professional system for the
most demanding, busy environment. Any test can be run at any time
in any order. The MDA II delivers accurate results quickly, safely
and efficiently. Throughput is high, regardless of the number
of assays being run.
Normalization of prothrombin time (PT) and activated partial
thromboplastin time (APTT) provides consistent results between
instruments, reagent lots and labs.
The MDA II's advanced optical system flags interfering substances,
ensures proper volume delivery and ensures optimal performance
of each assay. The MDA's patented Waveform Analysis Technology™
alerts the operator to abnormal waveform patterns.
The first of the MD/Alert Tools available is the A2 Flag™,
which flags the operator to the presence of the biphasic waveform.
This
atypical waveform has been associated with a potentially serious
coagulopathy such as seen in Sepsis and Disseminated Intravascular
Coagulation
and can occur even with a normal clotting time. The A2 Flag can
provide an early alert to the need for further clinical and
diagnostic
investigation.
Benefits
- rapid and accurate analysis
- waveform analysis provides additional information from routine
clotting assays
- minimal operator effort required
- easy to learn
- extreme operational flexibility
- fast and fail-safe loading of samples without run interruption
- high throughput (180 tests/hour), irrespective of assay type
and combination
- high level of operator safety
- automated quality control and quality assurance
Features
- clotting, chromogenic and immunoassy capability
- open and flexible assay/parameter definition
- photo-optical, 35 wavelength detection with 395 to 710 nm
Tungsten-Halogen light source
- 180 tests per hour; any test combination
- patented "Waveform Analysis" technology
- normalization of PT and APTT results between bioMérieux
instruments
- dyed PT and APTT reagents for volume delivery verification
- random access, batch or STAT modes
- up to 170 specimen tubes
- cooled reagent bay with 30 positions, allowing 12 assays on-line
- sampling of closed primary tubes
- STAT results without interruption of routine work-flow
- sample identification via automatic internal barcode scanning
- touch-screen operation on color monitor
- graphic display of reference and patient curves, clot waveforms
and reactions
- LIS connection
- modem connection for remote diagnosis and service
Assays
MDA II Methods:
- PT-Seconds, Quick Percent, INR
- APTT
- TT
- Fibrinogen
- Factor Assays
- ATIII
- Plasminogen
- Alpha-2-antiplasmin
- Protein C chromogenic
- Heparin anti-Xa
- Activated Protein C resistance
- Lupus Screen
- Lupus Confirmatory
- PNP
- Mixing studies
- Quantitative D-Dimer
Plus: open user programmable clotting, chromogenic and latex
methods for Protein S clottable, Reptilase, vWF antigen and more.
|
|