VIDAS / miniVIDAS: Healthcare

 
 
 

VIDAS / miniVIDAS: Healthcare Features & Specs

VIDAS miniVIDAS 	immonoassay systems	immunoassay tests
 
 
The VIDAS® immunoassay testing system uses a single-dose, ready-to-use reagent strip system
  • The SPR® (Solid Phase Receptacle) is coated with antigens or antibodies. (show picture)
  • The Strip contains all the reagents required for the reaction. (show picture)
 
The SPR acts as a pipetting and reagent transfer device. At each stage of the reaction, it aspirates the reagents in and out. This original concept prevents any inter-reagent or inter-sample contamination during immunoassay tests. In addition, the absence of tubing, syringes and needles reduces system maintenance to a minimum. (show picture)
 
The VIDAS system uses the ELFA assay principle, combining the ELISA test method with a final fluorescent reading. This technology ensures excellent result sensitivity and specificity.
  
Physical Features
 
Dimensions: 
  Vidas Blue Vidas
  Instrument packed Instrument Alone Instrument Packed Instrument Alone
Height 59 cm (23 1/4") 45 cm (17 5/9") 58.2 cm (23")

44.4 cm (max.) 

(17 1/2")

Width 110 cm (43 1/3") 88 cm (34 1/2") 99 cm (39") 84.7y cm (33 1/3")
Depth 66 cm (26" 55 cm (21 5/8") 67.5 cm (26 5/8") 52.4 cm (20 5/8"_
 
 
 
Space Requirements: 
   Vidas Blue Vidas
 Height   65 cm (25 5/8")  65 cm (25 5/8")
 Width   150 cm (59")  150 cm (59")
Depth   90 cm (35 1/2")  90 cm (35 1/2")
The instrument must be placed on a flat surface with a maximum horizontality defect of 5".
 
Weight
  Vidas Blue Vidas
  Instrument packed Instrument Alone Instrument Packed Instrument Alone
Mass 75 kg (165 1/3 lbs) 65 kg (143 1/2 lbs) 71 kg (156 1/2 lbs) 61 kg (134 1/2 lbs)
 
 
Sound level: 59 dBA
 

VIDAS® Specifications

 
Height: 23 inches (58 cm)
Width: 41.5 inches (105 cm)
Depth: 21.75 inches (68 cm)
Weight: 143 lbs (65 kg)
 
Stand-alone PC with printer, monitor, keyboard, and mouse (not included in listed dimensions)
 
Electrical requirements:
  • Voltage: 100-240 VAC
  • Electrical consumption: 3 - 1.2 A
  • Frequency: 50-60Hz
  • Power: 280 VA maximum
  • Heat emission: approximately 921 BTU/hr
 
Productivity:
  • Optimized cost per patient result
    • Uniquely designed testing device
    • Calibration stored in the analyzer's memory
  • Optimization of labor
    • Ready-to-use reagents
    • Minimum maintenance
    • Ease of use
    • Uni- or bidirectional interface to LIS
  • Rapid Results
    • Kinetic reactions
    • Automated
    • Efficient workflow
 
Flexibility:
  • Flexible work routine
  • "Sectioned" architecture – 5 sections, 6 tests each (30 total available)
  • "Add-on" modular system
  • Batch or single testing
  • STAT testing
  • Multiparametric testing
  • Load and Go
 
Quality:
  • Automation
  • No carryover contamination
  • Fluorescence reading
  • Ready-to-use, bar-code-labeled reagents
  • On-board QC program
 
 
 

miniVIDAS® Specifications

 
Weight: 88 lbs (40 kg)
 
Integrated computer screen, keyboard and printer
 
Electrical requirements:
  • Voltage: 100-240 VAC
  • Electrical consumption: 1.5 – 0.8 A
  • Frequency: 50-60Hz
  • Power: 150 Watts
  • Heat emission: approximately 512 Btu/hr
 
Productivity:
  • Optimized cost per patient result
    • Uniquely designed testing device
    • Calibration stored in the analyzer's memory
  • Optimization of labor
    • Ready-to-use, single-dose reagents (reagent strip and SPR®)
    • Minimum maintenance
    • Ease of use
    • Uni- or bidirectional interface to LIS
  • Rapid Results
    • Kinetic reactions
    • Automated
    • Efficient workflow
 
Flexibility:
  • Flexible work routine
  • "Sectioned" architecture – 5 sections, 6 tests each (30 total available)
  • "Add-on" modular system
  • Batch or single testing
  • STAT testing
  • Multiparametric testing
  • Load and Go
 
Quality:
  • Automation
  • No carryover contamination
  • Fluorescence reading
  • Ready-to-use, bar-code-labeled reagents
  • On-board QC program 
 
 
 
Downloads:
  

Next: VIDAS®/miniVIDAS® Uses >>